K-13 HIGH-R SYSTEM

CSI: 07 21 29 • 09 83 16
The K-13 High-R System is a mechanically supported insulation system for projects requiring a higher R-Value. With this system, K-13 is efficiently spray-applied up to 10” thick achieving up to R-37.5 to meet specifications.

K-13 Spray-Applied Thermal and Acoustical Insulation is an exposed ceiling finish requiring no additional barriers or materials. K-13 meets project requirements for thermal insulation, noise control with an attractive natural texture that is available in standard and custom colors.

HOW IT WORKS

PERFORMANCE & EFFICIENCY

With a mechanically supported system, K-13 High-R decreases risk for fallout found with typical high-build installations that require higher R-Value requirements for your project.

The K-13 High-R System begins with installing stickpins to the substrate and applying the first layer of K-13 up to 5” thick. This first layer of insulation is secured in place using StructaLath III, a unique welded lath wiring. The second layer of K-13 is then applied to meet project specifications for R-Value and color.

STEP 1

Install 6” stick pins starting 3” from wall in an approximate 16”x16” grid-like pattern.

STEP 2

Spray base layer of K-13 Tan to approximately 4”-5” thickness.

STEP 3

Place StructaLath III wiring over pins.

STEP 4

Secure the wiring to the pins with 1.5” washers.

STEP 5

Spray the final layer of K-13 to meet specifications for R-Value and color.

THERMAL CONTROL

K-13 is sprayed-in-place, filling cracks, seams, and voids to form a monolithic coating over the substrate helping to reduce air infiltration. Unlike prefabricated insulations, K-13 has no voids or compressed areas to reduce thermal efficiency, resulting in exceptionally low heat-loss characteristics and an R-Value of 3.7 per inch.

With the K-13 High-R System, K-13 is applied up to 10” to meet your higher thermal requirements, making it ideal for projects such as Parking Garages, Event Centers, Pre-Engineered Metal Buildings, or Stadiums.

K-13 R-VALUE CHART

ThicknessR-Value
1”3.7
2”7.5
3”11.25
4”15
5”18.75
6”22.5
7”26.25
8”30
9”33.75
10”37.5

SUSTAINABILITY

K-13 is made from 80% Pre-Consumer Recycled Content and inventoried to 1,000 PPM in accordance with the HPD Collaborative.

K-13 is UL GREENGUARD Gold certified and compliant with LEED v4: Low-Emitting Materials, CDHP/ California Section 01350, SCAQMD Rule 1168, and CHPS- Acoustical Ceiling. Additionally, K-13’s thermal and acoustical performance may contribute to sustainable credit categories for green-building initiatives.

K-13 does not contain silica dust, asbestos, mineral or glass fibers, or PCB’s.

Sustainable Credit Categories - LEED V4

MATERIALS + RESOURCES:

RECYCLED CONTENT:80% Pre-Consumer
REGIONAL MATERIALS: Manufactured by International Cellulose Corporation in Houston, TX.
MATERIAL INGREDIENT REPORTING: Inventoried to 1,000 PPM in accordance with the HPD Collaborative.

 

INDOOR ENVIRONMENTAL QUALITY:

INDOOR AIR QUALITY:
UL GREENGUARD Gold Certified
May Contribute Towards:
LEED v4: Indoor Air Quality Assessment
LEED v4: Enhanced Indoor Air Quality Strategies

THERMAL COMFORT:
Ure-K has exceptionally low heat-loss characteristics with an R-Value of 3.6 per inch, contributing R-4.5 at the standard 1.25″ application thickness.

ACOUSTICAL PERFORMANCE

LOW-EMITTING MATERIALS:
M1 Classified as a Low-Emitting Building Material Compliant With:
LEED v4: Low-Emitting Materials
CDHP/California Section 01350
SCAQMD Rule 1168
CHPS – Acoustical Ceiling

TECHNICAL DATA

ASTM Standards Compliance
  • ASTM C 423 – Sound Absorption
  • ASTM C 518 – Thermal Conductivity
  • ASTM C 739 – Cellulosic Fiber
  • ASTM C 1149 – Spray-Applied Cellulose Insulation
  • ASTM D 2244 – Light Reflectance
  • ASTM E 84 – Surface-Burning Characteristics
  • ASTM E 90 – Sound Transmission
  • ASTM E 736 – Cohesion/Adhesion – Bond Strength
  • ASTM E 759 – Bond Deflection
  • ASTM E 859 – Air Erosion
  • ASTM E 1042 – Acoustical Absorption
ASTM C 423 – Sound Absorption (NRC)

K-13 on Solid Backing

Inches125 Hz250 Hz500 Hz1,000 Hz2,000 Hz4,000 HzNRC
1”0.110.320.840.991.010.980.80
1.5"0.210.461.061.131.021.000.90
1.75”0.300.741.141.060.990.981.00
2”0.470.901.061.061.081.071.00
3”0.570.991.041.031.000.981.00
4”0.841.061.011.031.000.981.05
5”0.990.891.051.031.001.001.00

K-13 on 1.5” Metal Deck
Inches125 Hz250 Hz500 Hz1,000 Hz2,000 Hz4,000 HzNRC
1.5"0.360.891.261.071.011.001.05
3"0.971.041.130.990.950.981.05

K-13 on 2” Metal Deck
Inches125 Hz250 Hz500 Hz1,000 Hz2,000 Hz4,000 HzNRC
1"0.390.630.960.991.041.060.90
2"0.550.991.131.061.051.101.05

K-13 on 3” Metal Deck
Inches125 Hz250 Hz500 Hz1,000 Hz2,000 Hz4,000 HzNRC
1"0.500.660.971.021.051.030.95
1.5"0.550.921.111.020.950.991.00
2.75"0.690.981.171.030.971.041.05

All acoustical testing was performed by an NVLAP-accredited laboratory. Testing is available on request.

ASTM C 518 – Thermal Conductivity

R-Value: 3.7 per inch

K-13 R-Value Chart | ASTM C 518

ThicknessR-Value
1”3.7
2”7.5
3”11.25
4”15
5”18.75
6”22.5
7”26.25
8”30
9”33.75
10”37.5

ASTM D 2244 - Light Reflectance

K-13 Standard Color Light Reflectance Value

Standard ColorLight Reflectance Value (LRV)
White84+
Light Gray73+
Gray45+
Tan46+
Black17+

ASTM E 736 – Cohesion/Adhesion – Bond Strength

K-13: Bond Strength is greater than 150 psf

ASTM E 84 – Surface-Burning Characteristics

K-13 has a Class 1, Class A fire rating per ASTM E 84, UL 723, NFPA 255, and UBC 42.

Flame Spread – 5

Smoke Developed – 5

Underwriters’ Laboratories – Ref. #R5499

K-13 has been rated and approved by Factory Mutual Research Corporation.

Miscellaneous Codes & Approvals
  • Underwriters Laboratories – Classified Code Compliance Report UL ER 5499
  • Factory Mutual Research
  • Federal Defense Logistics Agency Cage Code: ONJU2
  • Federal Specification – SS-S-111C
  • Corps of Engineers Guide Specifications – CE-201.01
  • Department of the Navy Guide Specifications – NFGS-07218
  • EPA 40 CFR Part 248
  • Los Angeles – RR-24311
  • New York – MEA 65-96-M
  • Meets California Bureau of Home Furnishings Standards
  • Resource Conservation and Recovery Act

K-13 meets IBC 2009 Section 803.10 Stability requirements for Interior Finish materials.